Lot L0803-A: purity low

penguineer 0.1.0 · run 20261018T081350Z-b3b69f · 2026-10-18 08:13 UTC

purity was 98.2 wt% (spec ≥ 99) , sampled at SP-1 on 2026-08-03 07:59.

The leading hypothesis, with high confidence: TI-101.PV moved low.

Summary from the template.
purity: lot L0803-A against the reference lots

Hypotheses

#1 TI-101.PV high

process · score 0.97 · path E-101 → R-101 → S-product · dead time 50 min

TI-101.PV (E-101) ran 5.74 degC low from 2026-08-03 05:29, 50 min upstream of the sample point; purity moved when it arrived.

TestStrengthDetail
effect size 1.00 median moved -5.74 (-17.3 reference scales)
onset 1.00 step lands +0 min from the quality onset (tolerance 10 min)
lag correlation 0.89 r = +0.89 over 1440 reference points

Explains away:

#1 TI-101.PV shifted 50 min

#2 PT-100.PV medium

process · score 0.46 · path S-feed → E-101 → R-101 → S-product · dead time 52 min

PT-100.PV (S-feed) ran 1.02 bar low from 2026-08-03 05:27, 52 min upstream of the sample point; purity moved 55 min after the expected arrival.

TestStrengthDetail
effect size 1.00 median moved -1.02 (-43.3 reference scales)
onset 0.00 step lands -55 min from the quality onset (tolerance 10 min)
lag correlation 0.00 r = -0.29 over 1440 reference points, sign does not fit the deviation
#2 PT-100.PV shifted 52 min

E002: FIC-102 absorbed a disturbance: FI-102.PV held, output moved 9.1

#3 PI-103.PV medium

measurement fault · score 0.45 · path R-101 → S-product · dead time 45 min

PI-103.PV has a flatline finding in the lot window: value frozen at 5.968 for 90 min

Health warnings: H0001

#3 PI-103.PV shifted 45 min

Ruled out

CandidateWhy
FI-102.PVheld at setpoint by FIC-102 while its output moved 9.1 (+34.0 reference scales)
TI-104.PVits shift of -2.88 is 100% predicted from TI-101.PV (regression on the reference lots)
PI-103.PVdid not move in the lot

How this was worked out

Lot window2026-08-03 00:00 to 2026-08-03 08:00 at S-product
Quality onset2026-08-03 06:19 (AI-201.PV)
RegimeGRADE = 1
Reference lotsL0802-A (99.6), L0801-C (99.7), L0801-B (99.7)
Candidates tested5 tags, on a 60 s grid in material time
ConfidenceConfidence: high when the score is at least 0.4 and 0.025 ahead of the next hypothesis, medium from 0.25. Test weights: effect size 0.5, onset 0.3, lag correlation 0.3. Weights fitted on the homeostat train split (85 scenarios), thresholds chosen on the homeostat validation split (85 scenarios) (homeostat 0.1.0a3, bench plant 4144102c25e7).

Data health on the candidate tags

IDTagCheckSeverityFromDetail
H0001PI-103.PVflatlinewarning2026-08-03 05:59value frozen at 5.968 for 90 min